The Reduction of Modal Sensor Channels through a Pareto Chart Methodology

Abstract

Presented herein is a new experimental sensor placement procedure developed to assist in placing sensors in key locations in an efficient method to reduce the number of channels for a full modal analysis. It is a fast, noncontact method that uses a laser vibrometer to gather a candidate set of sensor locations. These locations are then evaluated using a Pareto chart to obtain a reduced set of sensor locations that still captures the motion of the structure. The Pareto chart is employed to identify the points on a structure that have the largest reaction to an input excitation and thus reduce the number of channels while capturing the most significant data. This method enhances the correct and efficient placement of sensors which is crucial in modal testing. Previously this required the development and/or use of a complicated model or set of equations. This new technique is applied in a case study on a small unmanned aerial system. The test procedure is presented and the results are discussed.

Document Details

Document Type
Pub Defense Publication
Publication Date
Jan 01, 2015
Source ID
10.1155/2015/869258

Entities

People

  • Kaci J. Lemler
  • William H. Semke

Organizations

  • United States Department of Defense
  • University of North Dakota

Tags

Readers

  • Computational Modeling and Simulation
  • Geodesy
  • Robotics and Automation.

Technology Areas

  • Autonomy
  • Directed Energy