Femtosecond coherent Raman system with >75 dB dynamic range for probing vibration modes across 250-2400 cm−1

Abstract

We report on the design and performance of a time-resolved Coherent Raman spectroscopy system with time resolution of better than 120 fs. The coherent transients can be traced with more than 75 dB dynamic range while accessing and probing Raman active modes across a 250–2400 cm−1 frequency. The system delivers an equivalent spectral resolution of better than 0.1 cm−1 regarding line bandwidth parameters for probed Raman resonances.

Document Details

Document Type
Pub Defense Publication
Publication Date
Jun 16, 2022
Source ID
10.1364/oe.460061

Entities

People

  • C. P. Neupane
  • Feruz Ganikhanov
  • G. P. Sharma
  • Helani A. S. Singhapurage
  • Jeremy Sylvester
  • R. M. D. M. Senarathna

Organizations

  • Air Force Office of Scientific Research
  • University of Rhode Island

Tags

Fields of Study

  • Physics

Readers

  • Control Systems Engineering.
  • Optical Physics and Photonics.