Evaluation of a 20-ft by 48-ft Straight-Sided Arch Roof, Prefabricated Metal Building, Northern Type, Manufactured by the Great Lakes Steel Corporation, Stran-Steel Division
Abstract
This building was evaluated to determine its adequacy for advanced-base use. The evaluation included a study of packaging and crating; erection; weathertightness; and structural adequacy for specified snow, wind, and floor loadings. The building can be packaged for overseas shipment in 230.4 cu ft with a gross weight of 10,010 lb. Erection of the building can be accomplished in 164.9 man-hr, using a 5-man team. The building is essentially watertight, structurally adequate for the specified loading.