DEVELOPMENT OF A PORTABLE DECONTAMINATION SHOWER UNIT

Abstract

A prototype decontamination shower unit incorporating a waste watar chlorination and recirculation system ha been designed by laboratory personnel. Construction, operation and water treatment tests have been made to aid in the further development of the unit, which has a capacity of 60 men per hour. Tests with BW simulants showed that a chlorine residual of 10 ppm at a pH of 6.7 resulted in rapid destruction of the BG and SMi test organisms in thei recirculated water. An objectionable mist from the showers was carried into the clean section of the unit. Tho unit will he redesigned to improve the various mechanical features and to incorporate a fan to exhauct the mist from the showers.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Apr 25, 1955
Accession Number
AD0081270

Entities

People

  • E. N. Hellberg
  • S. Giles
  • W. R. Nehlsen

Organizations

  • Naval Facilities Engineering Service Center

Tags

Communities of Interest

  • Counter WMD

DTIC Thesaurus Topics

  • Chlorination
  • Chlorine
  • Civil Engineering
  • Contracts
  • Decontamination
  • Developmental Tests
  • Engine Generator Sets
  • Engineering
  • Fresh Water
  • Government Procurement
  • Governments
  • United States Government
  • Waste Water
  • Water
  • Water Purification
  • Water Supplies
  • Water Tanks

Readers

  • Environmental Engineering
  • Military Science
  • Software Engineering