EVALUATION - DEVELOPMENT OF MIL-C-14157 CAPACITORS FOR NUCLEAR RADIATION ENVIRONMENT

Abstract

Six E-200 capacitors survived gamma irradiation tests and were subjected to environmental tests. Two units survived these tests. Half of the E-200 units in the control test failed within two hours. All of the inhibited oversized monoisopropylbiphenyl units failed in the gammatemperature environment; however, they survived for a longer period of time than the standard CPM08 capacitors. Some of the isocyanate treated Mylar and the Samica units were received and testing of these units was started. (Author)

Document Details

Document Type
Technical Report
Publication Date
May 01, 1961
Accession Number
AD0255995

Entities

People

  • E.r. Pfaff

Tags

DTIC Thesaurus Topics

  • Capacitors
  • Environment
  • Environmental Tests
  • Isocyanates
  • Nuclear Radiation
  • Radiation
  • Standards
  • Test And Evaluation
  • Test Methods

Readers

  • Mathematics or Statistics
  • Microwave Engineering.
  • Nuclear and Radiation Engineering.