Operation and maintenance instructions are presented for test set, electrical power QRC-133A(T). The test set was developed to enable maintenance personnel to monitor simultaneously, the voltage and current inputs of barrage jammer QRC-133A(T). The test set electronically consists of eight three-and-one half inch round flange (flush mounting) panel-type, electrical indicating meters (four voltmeters and four current meters) which are used to monitor primary input power of the QRC-133A(T) system, switching circuitry which permits testing the DC input under low and high load conditions, and properly rated fuses that protect the primary power input lines of the test set. (Author)