INHIBITION OF FLASHING OF AEROSOLS

Abstract

Experimental work included design, construction and operation of the aerosol generator and combustion tube; development of a photographic technique for determination of the drop size distribution; and determination of the variation of flammability limits with operating conditions. This latter phase indicated that the lower limit of flammability increases with the Sauter Mean Diameter (SMD) of the aerosol. Theoretical work included analysis of both stationary and falling aerosols. The former analysis predicted that limit concentrations would be independent of drop size. The latter analysis indicated a negligible variation of concentration with vertical distance; and consideration of the theoretical transverse variation predicted the experimentally observed increase of lower limit concentration with droplet diameter.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Mar 01, 1960
Accession Number
AD0256462

Entities

People

  • C. C. Miesse

Organizations

  • IIT Research Institute

Tags

Communities of Interest

  • Human Systems

DTIC Thesaurus Topics

  • Aerosol Generators
  • Air Flow
  • Boiling
  • Chemical Analysis
  • Combustion
  • Contracts
  • Equations
  • Flame Propagation
  • Flow Rate
  • Fluid Dynamics
  • Fluids
  • Ignition
  • Inhibition
  • Nitrogen
  • Photographs
  • Photography
  • Schematic Diagrams

Readers

  • Aerosol Science/Aerosol Physics
  • Combustion science or combustion engineering.