PERFORMANCE OF THE TAP-100 THERMOELECTRIC CONVERTER
Abstract
Designed and fabrication data are presented on the TAP-100 thermoelectric converter. Details of performance of the equipment are included. The device was operated to failure with the test program being divided into three parts as follows: (1) a preliminary evaluation during which a number of short runs were conducted so that loading and fuel consumption data could be obtained for various hot junction temperature levels, (2) a life test of the device, and (3) final testing, conducted just prior to disassembly. After testing the device was disassembled and the failure mechanics analyzed. Results indicated failure was caused by a combination of numerous internal shorts and severe junction breakdown. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Apr 01, 1961
- Accession Number
- AD0257312
Entities
People
- John E. Mccormick
Organizations
- Rome Laboratory