SM-2 6000 EKW (NET) NUCLEAR POWER PLANT - FINAL DESIGN SECONDARY SYSTEM

Abstract

A design analysis study of the SM-2 secondary plant equipment was undertaken to develop an SM-2 Final Design. Equipment sizes are based on utilization of a 28 tMW Pressurized Water Reactor and a 7500 eKW turbo-generator. Drawings showing equipment arrangement and over-all plant layout are provided. Studies were made on mechanical, structural and electrical design and all calculations are shown in the appendices of their respective sections. (Author)