THE PREVENTION OF STRAY VOLTAGE IN ELECTRO-EXPLOSIVE CIRCUITS
Abstract
A number of incidents have occurred involving the inadvertent actuation of electro-explosve devices, in various armament systems, by various sources of stray voltage. ome methods of circuit design and testing, which may be used to prevent such actuations are summarized. A number of steps which will contribute to the prevention of dangerous conditions caused by activation of an EED by stray voltage, are: (1) prevent stray voltage from reaching the EED; (2) mechanically lock the explosive system so that even if the EED's are fired a dangerous condition cannot occur; (3) decrease the response of the EED's to stray voltage; and (4) check the EED firing circuit for stray voltages.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 01, 1961
- Accession Number
- AD0261509
Entities
People
- Glenn R. Linsenmayer
Organizations
- Air Force Special Weapons Center