LINEAR LUMPED PARAMETER ANALYSIS OF SYNCHROS. VIII. SIMPLE DIFFERENTIAL CONTROL SYSTEMS,
Abstract
An analysis is presented of a differential control system. The system consists of a differential in series with a transmitter - transformer combination. The major goal is to express the various properties of the differential system such as voltage gradient, electrical error, and null voltage, in terms of the impedances. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Dec 10, 1953
- Accession Number
- AD0261645
Entities
People
- G. H. Weiss
- J. H. Rosenbloom
Organizations
- Naval Ordnance Laboratory