AN INVESTIGATION OF A SEMIAUTOMATIC IMPEDANCE INDICATOR
Abstract
An impedance indicator, which displays the impedance of a terminating load on an oscilloscope with a Smith chart overlay, was designed and built. The frequency range of the indicator is from 450 to 1000 mc and has a possible maximumAMPLITUDE ERROR OF APPROXIMATELY 13% above 500 mc. The average error is approximately 9.5%. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 01, 1961
- Accession Number
- AD0262906
Entities
People
- Richard Sundstrom
Organizations
- Denver Research Institute