UHF EXTENDED RANGE SECOR SYSTEM
Abstract
The technical problems, design criteria, and results of laboratory tests on the coherent carrier-correlation de ection kits and the model IV transponder are discussed in detail. These items are necessary to give the UHF, base timing, distance measuring equipment system an extended range capability. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 01, 1961
- Accession Number
- AD0264282
Entities
Organizations
- Cubic Corporation