INVESTIGATION OF MEANS FOR PREVENTING EXPLOSIVE FAILURES OF CASTABLE REFRACTORY
Abstract
IT WAS CONCLUDED THAT EXPLOSIVE RUPTURE OF CASTABLE REFRACTORY INSTALLATIONS DURING THEIR INITIAL HEATING PERIOD CAN BE PREVENTED BY THE ADDITION OF A SMALL PROPORTION OF SODIUM LIGNIN SULFONATE. The minimum proportion of additive required, 0.05 to about 0.10%, causes no adve se effects on the refractory, but excessive amounts might cause decreased strength. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 28, 1961
- Accession Number
- AD0264389
Entities
People
- R.c. Burt