15 KW TRANSMISSION LINE MATCHING TRANSFORMER
Abstract
INVESTIGATIONS WERE MADE IN THE DESIGN OF 2 TRANSMISSION LINE MATCHING TRANSFORMERS WHICH OPERATE OVER THE FREQUENCY RANGE 2 TO 30 MC WITH A POWER RATING OF 15 KW, 100% modulated, and which are capable of transforming an unbalanced primary load (70 ohm resistive impedance with a VSWR no greater than 3 to 1) to a balanced secondary load (600 ohm impedance with a VSWR no greater than 3 to 1). Redesign of the transformer and detail drawings were completed. Fabrication of parts and assembly of units were also completed. Low power tests were continued. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 30, 1961
- Accession Number
- AD0265433
Entities
Organizations
- Westinghouse Electric Corporation