THE DESIGN AND DEVELOPMENT OF A ONE-HALF WATT HEATER POWER REDUCED SIZE NUVISTOR TRIODE

Abstract

Design of the final version of the half size nuvistor designated as the developmental typeA15274 was completed. A few initial samples of this tube were completed. Heater power input was fixed at 400 milliwatts and a 700 mc noise figure of 7.5 db is attainable at 400 milliwatts plate power input. Practical difficulties in grid fabrication delayed fabrication of sufficient ube samples for more complete electrical and mechanical testing. (Author)

Document Details

Document Type
Technical Report
Publication Date
Jun 30, 1961
Accession Number
AD0266111

Entities

People

  • W.j. Helwig

Tags

Communities of Interest

  • Energy and Power Technologies

DTIC Thesaurus Topics

  • Fabrication

Readers