STUDY OF SELF-LEVELING PNEUMATIC VIBRATION ISOLATION, PHASE I
Abstract
Dynamic response is determined for a single mount system by analysis and the use of an analog computer. Both step and sinusoidal inputs of base movement and force on the mass are considered. This air mount system consists only of the isolated mass, the air mount bags, a relatively small booster valve, a relatively small leveling valve, an air pressure supply, and the interconnecting piping. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Oct 31, 1961
- Accession Number
- AD0272058
Entities
People
- C.s. Duckwald
- J.r. Colston
- W.a. Boothe
Organizations
- General Electric