RESEARCH ON DISPLACEMENT GAGES. MECHANICAL PENDULUM GAGE

Abstract

For evaluation of the effects of nuclear or chemical explosions underground, the horizontal and vertical displacement of the ground nearby needs to be measured. Integration of accelerometer or velocity gage records is unsatisfactory, and direct displacement measurement is desired. The aperiodic gages developed earlier give an output directly proportional to displacement, but had certain major operational drawbacks. These have been eliminated by changing to long period seismic gages--though at the cost of the convenience of direct proportionality between output and displacement. Tests of a prototype of this type of gage show errors of less than 10% full range for periods of operation up to 2 secs. Calibration procedures and a numerical method for converting the output to displacement are given in detail. (Author)

Document Details

Document Type
Technical Report
Publication Date
Jun 01, 1961
Accession Number