A FAILURE TO FIND EFFECTS OF FUNCTION WORDS ON SERIAL POSITION CURVES IN FREE RECALL OF A RANDOMLY SELECTED LIST OF WORDS

Abstract

Tests were conducted on High Capacity Vented Nickel-Cadmium Cells (24 each of 6 types). None of the cells met the specified physical dimensions, mainly due to bulging in the length dimension; only 5 of the 144 cell vents passed the Vent Plug Release Test, the majority of failures resulting from plugs not releasing at the specified upper limit; cell types BB-437, 418, 438 and 439 failed to meet the discharge requirements after high temperature charged storage at 165 ! 2 F. for one week; 3 of the 8 cells, type BB-437()/U failed the High Frequency Vibration Test and 11 of the 24 cells of this type failed the Full Capacity Discharge Test on Cycle 6. On a retest, 8 of 11 of these cells failed. Although some cell types appeared to have failed the Low Temperature Test on Cycle No. 2, a retest, after restraining the cells to their proper dimensions and readjusting the electrolyte to 1.300 specific gravity, indicated that the cells met this requirement. (Author)

Document Details

Document Type
Technical Report
Publication Date
Jul 01, 1962
Accession Number
AD0284604

Entities

People

  • Charles N. Cofer

Organizations

  • New York University

Tags

DTIC Thesaurus Topics

  • Doppler Effect
  • Electrolytes
  • Frequency
  • Frequency Bands
  • Frequency Shift
  • High Temperature
  • Low Temperature
  • Radio Frequency
  • Specific Gravity
  • Vibration

Readers

  • Battery Technology and Engineering
  • Brain and Cognitive Science; Experimental Psychology; Cognitive Neuroscience
  • Explosive Engineering.