ELECTRICAL SYSTEM - INSULATED ELECTRICAL WIRE - INVESTIGATION OF MOISTURE RESISTANCE TEST PROCEDURES
Abstract
Test setups consisted of 5 methods of checking moisture resistance characteristics of insulated wire by the use of NaCl solutions. Each setup is described in detail and evaluated by comparing the insulation resistance obtained by it with the insulation resistance obtained by the longer and more involved moisture resistance test of MIL-C-5015C. The insulation resistance of the wires was determined at the start of each test and at various intervals during the test. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Dec 10, 1959
- Accession Number
- AD0287938
Entities
People
- Weldon Young
Organizations
- General Dynamics