HYDROSTREAK WATER SCOOP STUDY
Abstract
A new vertical free-jet hydrodynamic test facility is checked out during a series of tests of ram inlets, fully submerged bodies and discs, surface piercing struts, and low aspect ratio planing models. Test conditions include Froude number of infinity, cavitation number of zero, and Reynolds Number of 1.5 x 10 to the 6th power. Excellent agreement is found with available results from the literature wherever comparison is possible. Cambered and flat planing surfaces of several plan forms are tested from initial water contact through full wetting to deep submergence. Lift drag ratios near 10 are found in several cases. A complete water scoop configuration is established for high speed overwater vehicle application and its lift, drag, and pressure recovery fully validate the scoop performance assumptions incorporated into previous Hydrostreak performance estimates.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 01, 1962
- Accession Number
- AD0290312
Entities
People
- N. B. Hirsh
- R. W. Mcjones