CALCULATION OF A TRI-PHASE HEATER WITH ANGULAR ELECTRODES
Abstract
The field in the central zone of a 3-phase electrode preheater appears to be rotating, elliptical. In zones between sections of electrodes extending from the corresponding peaks by more than 0.5 diam. the field can be considered as pulsating. The derived formulas allow one, with sufficient practical accuracy, to calculate the power scattered by a tri-phase electrode preheater. The described method of determining power scattered in the zone of the rotating field can be utilized in calculating polyphase preheaters with electrodes of different form. (Author)