CRITICALLY-DAMPED COMPENSATION FOR BROADBAND AMPLIFIERS
Abstract
Lossless critically-damped 2-ter inal and 3-terminal ladders are considered as a means of compensating for parasitic shunt capacitance in broadband amplifiers. Equations are presented that simplify the design of these ladders. The capacitance and inductance values are tabulated for ladders that contain up to 7 reactive elements. The analysis is extended to the limiting case of an infinite number of elements. The element values and transient responses of these optimum ladders are derived. Using a figure of merit that is based on the slope of the step response at its half-amplitude point, the infinite 2-terminal ladder is 59% better than an uncompensated circuit while the 3terminal ladder is 117% better. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 23, 1962
- Accession Number
- AD0293853
Entities
People
- Sid Deutsch
Organizations
- New York University Tandon School of Engineering