COMBUSTION PROBLEMS IN ORR AND SEMBOWER INCORPORATED 800 LBS/HR AUXILIARY BOILER (MSO CLASS)

Abstract

The existing burner on the Laboratory's boiler was modified to correspond to that furnished on the MSO-522 Class units. Operating trials were still characterized by pulsations. Operating trials with a new blower system revealed no improvement in combustion performance. Various burner modifications were made and evaluated using both the original and the new blower assemblies. Satisfactory results were finally obtained after several modifications were made to the burner air nozzle arrangement.