SKUDROL 500 HYDRAULIC FLUID RESISTANCE OF EC 1290 SCOTCHWELD PRIME + AF 10 ADHESIVE BONDED JOINTS

Abstract

Slight softening of the EC 1290 occurred after twelve days immersion at ambient temperature. Additional softening was not observed during eighteen additional days of immersion. Tensile shear and peel test specimens using the EC 1290 primer and AF-10 adhesives were immersed in Skydrol 500 hydraulic fluid for thirty days at ambient temperature. At the end of thirty days immersion tension shear and peel strength tests were made. These tests showed that the Skydrol 500 hydraulic fluid had no significant deleterious effect upon the adhesive bonded joints.