OPERATIONAL EVALUATION OF RADIO TRANSMITTER SET AN/MRT-4(XL-1) EW SYSTEMS TEST USAEPG-3, PHASE II, EQUIPMENT TEST AND EVALUATION.
Abstract
The results of two field tests of radio transmitter set AN/MRT-4(XL-1) are set forth. The first test determined the interference which the jammer causes to a division-area grid communications system employing Radio Terminal Set AN/TRC-24; the second test determined the jammer interference to a VHF circuit employing the airborne radio set ARC Type 12. It was found that the jammer must be separated from any terminal of a grid equipped with the AN/TRC-24 by a distance of 1 mile to avoid disruption teletype communications. The ARC Type 12 receives significant interference within 1/2 mile of an AN/MRT-4(XL-1), but beyond that distance can operate through minor interference. Also see AD-311 203. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- May 01, 1957
- Accession Number
- AD0311204