SPOT AND FUSION WELD FATIQUE CHARACTERISTICS
Abstract
The fatigue of 10 per cent cold worked and aged (1500 F) Eaynes Stellite Co., R-235 nickel base alloy spot weld lap and fusion weld butt Joints was determined at room temperature and 1500 F with a 4/9 test u1timate strength maximum fatigue load. Spot welds were tested in thickness combinations of 0.020" to 0.020", 0.020" to 0.040" and 0.040" to 0.063", and fusion weld thickness combinations were 0.016" to 0.016", 0.040" to 0.040" and 0.063" to 0.063". Fatigue life data are given.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 20, 1959
- Accession Number
- AD0402169
Entities
People
- E. Schiff
- G. D. Lindeneau
- W. E. Wise
Organizations
- General Dynamics