HIGH POWER, HIGH VOLTAGE, AUDIO FREQUENCY TRANSFORMER DESIGN MANUAL
Abstract
Research is presented on the investigation and verification of data and design methods used to design high power, high voltage, audio frequency transformers. Ratings of these transformers fall within the following characteristics: (a) peak power levels from 15 to 350 kilowatts; (b) operating frequencies from 20 to 20,000 cps; (c) peak voltage ratings from 4,000 to 28,000 volts; and (d) impedance levels of 300 to 3,000 ohms primary and 10 to 1,2000 ohms secondary. The scope of this work includes a discussion of the mechanical and packaging aspects of the de sign, the insulation materials and processing of those materials, and the electrical and magnetic characteristics of audio frequency transformers.
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 31, 1963
- Accession Number
- AD0403400
Entities
Organizations
- General Electric