DEVELOPMENT AND CONSTRUCTION OF WATERTIGHT CABLES RG 11 A/U RG 217/U RG 218/U
Abstract
The main objectives are as follows: (a) Atten uation - Very low losses have been achieved with the cables as now fabricated. (b) Flexibility The standards set up in the pertinent specification have been met, but this is one area where an improvement could be attained. (c) Hydro static - All cables have gone to 1000 PSI with 0 leakage over the specified time. (d) Mechanical Ability - All cables have passed this 1000 cycles abrasion as set up in MIC-915 with a great deal of margin. (e) All cables have met the capacitance and impedance requirements.
Document Details
- Document Type
- Technical Report
- Publication Date
- Apr 25, 1963
- Accession Number
- AD0405558