ELECTRO-INTERFERENCE TEST REPORT ON POWER SUPPLY GROUP (FIGURE A 1284)

Abstract

The test sample was tested. Broadband, interference tests, both radiated and conducted, were performed. Susceptibility tests were also performed. Radiated, broadband, transient interference, generated by manually operating relays and circuit breakers, exceeded the limits above 0.1 megacycles. Radiated, broadband, steady state interference exceeded the limits between 0.5 to 1.2 megacycles in some modes. Broadband, conducted, transient interference, measured on ac and dc power leads, exceeded the limits above 30 kilocycles on some lines. Conducted, broadband, steady-state interference measured on the ac and dc power leads exceeded the limits above 15 kilocycles on some lines. Susceptibility tests indicated that the voltage of the test sample did not deviate from its normal steady state output.