DESIGN AND MANUFACTURE OF SEALED NICKEL CADMIUM CELLS OF CYLINDRICAL DESIGN TO SIGNAL CORPS TECHNICAL REQUIREMENT SCL-7504A, JUNE 28, 1961

Abstract

The 60 cells of each of three sizes (10 A.H., 50 A.H. and 100 A.H.) were manufactured. The qualification tests of SCL-7504A were success fully passed and all cells were delivered. All 10 A.H. and 50 A.H. cells had teflon sealed terminals. In the 100 A.H. size, 40 cells had teflon seals and 20 cells had ceramic seals. Fifty each of the 50 A.H. and 100 A.H. cells were partially scored to immobilize te assembly in order to withstand the severe vibration and shock requirements of SCL-7504A. Parts lists and pertinent drawings of all types of cells are included in this report.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Mar 31, 1963