ADVANCED SOLAR THERMIONIC GENERATORS

Abstract

Fabrication of advanced solar thermionic converters, both B and C series, is outlined, noting the significant problem areas. Results of testing of the B series have given per formance up to 9.6 watts/cm2 at 1950 K and 3.0 watts/cm2 at 1550 K. Converter C-3 has com pleted a 510 hour test, including 210 hours of thermal cycling. Electron beam welding of rhenium resulted in a brittle phase and leaking joints.