FUNCTIONAL TEST PROCEDURES FOR ABLATION METERS AND CALORIMETERS FOR MINUTEMAN R+D MISSILES,

Abstract

The objective of this document is to provide requirements and procedures for functional test ing the airborne calorimeters and ablation gages to be used in the minuteman R+D missiles. The document is divided into two sections; Section 1 is devoted to the test requirements and pro cedures for calorimeters and Section 2 is devoted to the test requirements and procedures for calorimeters and Section 2 is devoted to the test requirements and procedures for ablation g Each section includes data sheets that are to be filled out completely for each unit during testing and submitted to the Transducers and Signal Conditioners Group of the Instrumenta tion Unit immediately after the testing is completed. (Author)

Document Details

Document Type
Technical Report
Publication Date
Sep 23, 1960
Accession Number
AD0413443

Entities

People

  • E. Mills

Organizations

  • Boeing

Tags

Communities of Interest

  • Weapons Technologies

DTIC Thesaurus Topics

  • Ablation
  • Airborne
  • Calorimeters
  • Intercontinental Ballistic Missiles
  • Transducers

Readers

  • Computer Science/Computer Engineering/Data Science/Digital Signal Processing.
  • Library and Information Science
  • Pulsed Power and Plasma Physics.