NOTES ON TESTS OF INSERTS USED IN HAWK WARHEAD XM5E3,
Abstract
Torque tests were made on threaded inserts of the HAWK Warhead, XM5E3 because of reported problems from loose inserts and cracks in he plastics, and loose inserts in the S + A liner and warhead mounting lugs. An improved method of holding the inserts in the plastic resulted from these tests. Production changes were made incorporating these new design features. (Author)