MAGNETICALLY CONTROLLED GAS DUPLEXER.
Abstract
An experimental setup for making measurements of discharge arc loss in a magnetic field is de scribed in detail. Attempt is made to explain recovery time reductions in a transverse magnetic field by calculating the fractional power trans mitted into a magnetized semi-infinite plasma. The resulting theoretical reductions are much smaller than those observed experimentally. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 01, 1963
- Accession Number
- AD0418169
Entities
People
- C.s. Ward
- M.a. Allen
Organizations
- M/A-COM Technology Solutions