PROCESSING - CONVENTIONAL CHROMIUM PLATE ON HIGH STRENGTH STEEL, PROTECTION BY SPECIAL CORROSION INHIBITOR FLUID, EVALUATION OF,

Abstract

A satisfactory, improved corrosion resistant treatment was found for conventional chromium electroplate of 0.0020 to .0025 in. thickness. It is FMS 0003 epoxy primer. (Author)

Document Details

Document Type
Technical Report
Publication Date
Nov 04, 1963
Accession Number
AD0423074

Entities

People

  • E. W. Turns

Organizations

  • General Dynamics

Tags

DTIC Thesaurus Topics

  • Chromium
  • Corrosion
  • Ferrium
  • Inhibitors
  • Steel
  • Test And Evaluation
  • Thickness

Readers

  • Munitions and Ordnance Engineering
  • Surface Engineering/Surface Coating Technology.