INVESTIGATION OF METHODS LEADING TO THE DETERMINATION OF THE STATE OF CHARGE OF NICKEL CADMIUM BATTERIES.
Abstract
Using an improved bridge circuit, the equivalent circuit components of a nickel-cadmium cell were measured at frequencies of 10, 20, and 200 cps at various states of charge. The measurements were made on a group of vented cells. It was found that the equivalent circuit components, especially R sub c at 10 and 20 cps changed with time. A correlation of R sub c with residual capacity was found after cells were stored for more than four hours after discharge. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 01, 1963
- Accession Number
- AD0426951
Entities
People
- H.n. Seiger
- J. Wartell