TECHNICAL EVALUATION OF FIELD INTENSITY METER NM-52A.

Abstract

The Radio Interference-Field Intensity Meter NM-52A was technically evaluated and compared to its prototype, Radio Test Set AN/URM-17. The NM-52A is a superior Field Intensity Meter to the AN/URM-17; however, there are a number of deficiencies which should be corrected prior to acceptance for service use. The NR-52A operates over a frequency range of 375 to 1000 MC. (Author)

Document Details

Document Type
Technical Report
Publication Date
Mar 03, 1961
Accession Number
AD0427923

Entities

People

  • Claude M. Wooten

Organizations

  • Naval Air Station Patuxent River

Tags

DTIC Thesaurus Topics

  • Deficiencies
  • Frequency
  • Intensity
  • Prototypes
  • Radio Interference
  • Test And Evaluation
  • Test Sets

Fields of Study

  • Physics

Readers

  • Aerospace Test and Evaluation