THERMOELECTRIC TEMPERATURE CONTROL IN AN/URQ-9 FREQUENCY STANDARD.

Abstract

Temperature stability measurements within the thermoelectrically controlled temperature crystal chamber were made with high accuracy. Temperature was found to be controlled to within = 0.01 degrees C of the set point. Frequency measurements made on six l w temperature 5 mc crystals are plotted to show their frequency stabilization period and long term aging characteristics. Long term drift rates of precision oscillators coupled to the low temperature crystals were found to be within several parts in 10 to the -11th power per day. Turning-point curves for two of the low temperature crystals w re determined and plotted. Performance of the six oscillators after periods of shutdown are reported. The units showed a short stabilization period of a few hours and then went into a new aging curve. (Author)

Document Details

Document Type
Technical Report
Publication Date
Jan 15, 1964
Accession Number
AD0430292

Entities

People

  • A. L. Wennerberg

Organizations

  • Whirlpool Corporation

Tags

DTIC Thesaurus Topics

  • Accuracy
  • Frequency
  • Frequency Standards
  • Low Temperature
  • Measurement
  • Oscillators
  • Standards
  • Temperature Control

Readers

  • Materials Science and Engineering.
  • Positioning, Navigation, and Timing (PNT) Technology.