DEVELOPMENT OF FIELD DATA CABLE.

Abstract

The use of litz conduct6rs does not improve pulse transmission conditions and the use of such is conclusively not warranted. Data compiled in this report show that a construction of a coaxial component utilizing a conductor of 19/34 S.C. or 19/34 T. C. subscantially improves the transmission characteristics. Although a cable having a conductor of nineteen strands of 34 AWG Alloy 63 with a silver plate was not constructed and investigated during this interval it is believed that if constructed the transmission qualities will approximately be equal to that of S.C. or tinned copper and at the same time show a marked improvement mechanically. Any mechanical improvement will be advantageous when testing to MILC-13777. (Author)

Document Details

Document Type
Technical Report
Publication Date
Dec 31, 1963
Accession Number
AD0433255