EVALUATION TESTS OF FLOAT-ACTUATED ELECTRICAL LIQUID LEVEL INDICATING SYSTEM MANUFACTURED BY LIQUIDOMETER CORPORATION.
Abstract
Performance evaluation and shock tests were made on an electrical liquid level indicating system provided by the Liquidometer Corporation. The system was not affected by vibration, temperature or line voltage variations and the response time constant was less than 0.1 seconds. The average non-linearity of the system is 0.9%. In addition, the system will meet the requirements for shock service after the manufacturer makes the recommended modifications. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 12, 1964
- Accession Number
- AD0433957
Entities
People
- R. A. Hammaker