MILLIMETER WAVE DIODE FABRICATION,
Abstract
Receivers and measuring instruments operating in the millimeter wave length portion of the spectrum require wave guide components utilizing point contact diodes. Some of these components in the very short wave length range (less than 4 mm) are not commercially available and must be fabricated in the laboratory. This report describes the technique for fabricating diodes used in millimeter wave detectors, mixers and multipliers. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 01, 1964
- Accession Number
- AD0434047
Entities
People
- Donald Bauerle
Organizations
- Ballistic Research Laboratory