MATERIAL - LUBRICATING OIL - GTO-790 - IRRADIATION UNDER STATIC AND DYNAMIC CONDITIONS EFFECTS OF,
Abstract
A dynamic pump loop system, was operated for 50 hrs. in a non-nuclear environment to establish base line data on the functional fluid which was GTO-790. The system was then subjected to operation in a nuclear environment. Dynamic and static oil samples were taken periodically to determine physical and chemical property changes of the test fluids. Average bulk oil temperature was 285 F. The irradiation run was terminated after 19.5 hrs. because of decreasing flash point values. The effects of simultaneous dynamic operation and irradiation on GTO-790 fluid did not appear to be synergistic. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 07, 1960
- Accession Number
- AD0437238
Entities
People
- R. H. Mcdaniel
Organizations
- General Dynamics