LOW-GRAVITY POOL-BOILING HEAT TRANSFER.
Abstract
The results are presented of an investigation into the characteristics of pool boiling at reduced gravity. Experimental data taken in a 1.8-second drop tower, using water as the test fluid, are given for a 0.020-inch diameter platinum wire and 1/8-inch and 1/4-inch platinum ribbons. In the range of nucleate boiling no significant influence of gravity or geometry was observed whereas the critical heat flux was affected by both gravity and the geometry of the container as well as by the time at reduced gravity. (Auchor)
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 01, 1964
- Accession Number
- AD0437803
Entities
People
- Robert Glen Clodfelter
Organizations
- Air Force Research Laboratory