' 'K' ' FACTOR DETERMINATION OF FOUR TYPES OF PANEL CONSTRUCTION IN F-111 AIRPLANE,
Abstract
Thermal conductivity measurements were made on panels designed to insulate certain areas of the F-111 airplane fuel tank. Four general types of panels were tested: Type I. All fiberglass panels exhibited the lowest ''K'' factors of all panels at mean temperatures below 300 F. Type II. An aluminum skin-fiberglass core panel exhibited a steep slope when ''K'' was plotted against temperature. Type IV. Microglass balloon filled panel tests revealed that higher glass concentrations of the coating result in lower ''K'' factors. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Apr 15, 1964
- Accession Number
- AD0438470
Entities
People
- M. S. Staggs
Organizations
- General Dynamics