DETERMINATION OF RESPONSES OF PROTECTED AND UNPROTECTED ELECTRIC INITIATORS TO ELECTRICAL STIMULI. SPECIAL TECHNICAL REPORT ON WESTON 50-WATT LOW BANDPASS TRANSFORMER.

Abstract

The effectiveness of two samples of a 50-Watt Low Bandpass Transformer (LBT) against electromagnetic fields was measured over the frequency range from 100 cps to 10 gc. The effectiveness of each device is reported in terms of power attenuation (PA), and minimum possible insertion loss (ILr). Directly measured data from which these evaluation parameters were computed is reported in tabular form. (Author)