RECALIBRATION OF STANDARD CARD-GAP TEST

Abstract

A new calibration of peak pressure (P) vs gap length (X) is presented for the NOL standardized and modified gap tests. It is shown that experimental values of both shock velocity (U) and particle velocity (u) are required to obtain a valid P-X curve at low pressures, because the normally linear U-u curve for the gap material exhibits a discontinuity at about X = 50 mm. The initial free-surface velocity is determined by monitoring films placed at the end of the gap.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Aug 20, 1965
Accession Number
AD0470648

Entities

People

  • Donna Price
  • Thomas P. Liddiard Jr.

Organizations

  • Naval Ordnance Laboratory

Tags

Communities of Interest

  • Weapons Technologies

DTIC Thesaurus Topics

  • Abstracts
  • Accuracy
  • Data Reduction
  • Discontinuities
  • Errors
  • Explosions
  • Explosives
  • Materials
  • Materials Laboratories
  • Materials Science
  • Measurement
  • Munitions
  • Ordnance Laboratories
  • Pentolite
  • Plastic Explosives
  • Plexiglas
  • United States

Fields of Study

  • Physics

Readers

  • Combustion Dynamics and Shock Wave Physics.
  • Software Engineering