TYPE APPROVAL TESTS OF SYNCHRO CONTROL TRANSFORMER TYPE 3CTB MK12 MOD 3, MANUFACTURED BY FORD INSTRUMENT COMPANY,

Abstract

Three synchro control transformers Type 3CTB MK12 Mod 3 were subjected to type approval tests of OS 671 Revision E for conformance. The units failed in the following respect: serial number 5 exceeded the maximum minimum-voltage requirement of 0.040 volts by 6 millivolts. (Author)

Document Details

Document Type
Technical Report
Publication Date
Aug 23, 1950
Accession Number
AD0477319

Entities

People

  • A. J. Lovell
  • J. Havrylak

Organizations

  • Naval Ordnance Laboratory

Tags

DTIC Thesaurus Topics

  • Transformers

Readers

  • Aerospace Test and Evaluation
  • Electrical Engineering