PM-1 NUCLEAR POWER PLANT CATEGORY III SYSTEM/COMPONENT TESTS,

Abstract

Performance testing data were compiled and evaluated for 13 specific performance evaluation areas. Each is detailed as a section of the report. It was concluded that further consideration should be given to improve the performance of: the main air cooled condenser, the main generator frequency and voltage control, over-all instrumentation calibration and general control system tuneup, the primary coolant makeup source and the tritium levels in the primary systems. Remedial action may be required in certain of these areas.

Document Details

Document Type
Technical Report
Publication Date
May 01, 1966
Accession Number
AD0482637

Entities

People

  • Howard C. Zachman
  • Leigh D. Hassell
  • Peter Reichelsdorfer
  • Ronald Dugas
  • William C. Hall

Tags

DTIC Thesaurus Topics

  • Air Cooled
  • Calibration
  • Control Systems
  • Electric Generators
  • Electric Power Plants
  • Energy Systems
  • Frequency
  • Generators
  • Instrumentation
  • Measuring Instruments
  • Nuclear Power Plants
  • Performance Tests
  • Test And Evaluation

Readers

  • Electrical Engineering
  • Software Engineering