HIGH RESOLUTION CATHODE RAY TUBE EVALUATION.

Abstract

This report outlines and provides a means of comparing the four basic methods of CRT testing now employed by the cathode ray tube industry. An analysis of each test method, its restrictions, limitations, and advantages are discussed along with the basic requirements for testing cathode ray tubes. These four methods are selected by a joint industry-government committee as possible test standards. They are: (1) Shrinking Raster Technique, (2) Schade Spatial Frequency Technique, (3) Line Profile and Single Slit Technique, (4) Double Line Trace Technique (Westinghouse Method). Five high resolution cathode ray tubes were subjected to the four methods of tests and the results indicated for comparison. The appendix gives a detailed description of the CRT Analyser designed and built by Data Corporation for performing the various tests described. (Author)